Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Aust Endod J ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38596885

RESUMO

This study investigated the effect of the timing of primary endodontic treatment and dosage of radiotherapy on the remaining filling material (RFM) during endodontic reintervention. 60 single-rooted human mandibular premolars were distributed into five groups (n = 12), according to the timing and dosage of radiation (55Gy or 70Gy): NegativeCG-non-irradiated teeth; Endo-pre-RT55/70-obturation before irradiation (55Gy or 70Gy); Endo-post-RT55/70-obturation and reintervention after irradiation (55Gy or 70Gy). Roots were cleaved and analysed under stereomicroscope and Scanning Electron Microscope to quantify (%) the RFM. Experimental groups had a significantly greater amount (p < 0.05) of RFM in the middle and apical thirds than the control group, except for Endo-pre-RT55 in the middle third (p < 0.0001). The apical third had greater amount of RFM (p < 0.05). Radiation therapy, before and after primary endodontic treatment, increased the amount of RFM, regardless of the dose delivered. When necessary, reintervention preferably must be performed before radiation therapy.

2.
Odontology ; 112(1): 51-73, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37561273

RESUMO

The aim of this study was to perform an integrative review to identify the most effective supplementary protocols used after filling material (FM) removal and root canal reinstrumentation, during endodontic reintervention. The literature search was performed on the electronic databases PubMed and Latin American and Caribbean Health Sciences Literature (LILACS), using a combination of specific scientific descriptors. Selection criteria accepted articles published in English, Spanish and Portuguese languages, up to August 2021, involving in vitro and ex vivo studies. After applying the eligibility criteria, 46 articles were included for qualitative analysis. The tool for qualitative analysis of quasi-experimental studies of the Joanna Briggs Institute was used to determine the risk of bias of the included articles. The selected articles provided important data regarding the following supplementary protocols: sonic and ultrasonic activation of the irrigating solution; the use of ultrasonic inserts, XP-endo system instruments, and photon-induced photoacoustic streaming for mechanical debridement; and new devices as GentleWave system, and the self-adjusting file. Overall, all supplementary protocols demonstrated efficacy in removing the remaining FM. The implementation of various supplementary protocols can effectively remove the remaining FM from the root canal walls, although complete removal is not always achieved. However, it was not possible to determine the most effective protocol. Conversely, their association can enhance remaining FM removal. Remaining FM attached to root canal walls hinders proper chemical-mechanical preparation during endodontic reintervention. Supplementary protocols optimize the remaining FM removal, enhancing cleaning and disinfection of root canal.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X , Guta-Percha , Cavidade Pulpar
3.
Microsc Res Tech ; 87(2): 315-325, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37811954

RESUMO

The interaction of sodium hypochlorite (NaOCl) and chlorhexidine gluconate (CHX) produces an orange-brown precipitate. The present study evaluated the influence of distilled water (H2 O) in different irrigation protocols designed to prevent the formation of precipitate with NaOCl and CHX. Fifty canine teeth were instrumented and split longitudinally. The canal was examined with a stereomicroscope and photographed by canal-thirds. The tooth halves were repositioned and distributed randomly into five groups, according to the final irrigation protocol (n = 10): G1 (control)-Ethylenediaminetetraacetic acid (EDTA) + NaOCl + CHX, conventional irrigation (CI); G2-EDTA + NaOCl + CHX, activated with passive ultrasonic irrigation (PUI); G3-EDTA (PUI) + NaOCl (PUI) + H2 O (CI) + CHX (PUI); G4-EDTA + NaOCl + H2 O + CHX (PUI); G5-EDTA (PUI) + NaOCl (PUI) + H2 O (continuous ultrasonic irrigation [CUI]) + CHX (PUI). The specimens were evaluated with a stereomicroscope and scanning electron microscope (SEM). Energy dispersive x-ray spectroscopy analysis was performed to identify the elemental profile of the irrigated canal walls. The images were scored according to the extensiveness of precipitate. Data were analyzed (Kruskal-Wallis test, α = 5%). Under the stereomicroscope, G1 had significantly higher scores than all the other groups in all canal-thirds (p < .05). All four experimental groups showed similar scores (p > .05). There were no significant differences in precipitate formation among root-thirds in intragroup analysis (p > .05). Upon SEM examination, overall, only G5 had lower scores than G1 (p < .05). Analysis by canal-thirds showed no significant difference among groups and among canal-thirds in the intragroup analysis (p > .05). G1 showed high Cl peaks. In-between irrigation with H2 O activated by CUI is effective in preventing precipitate formation during canal debridement with NaOCl and CHX. RESEARCH HIGHLIGHTS: Continuous ultrasonic irrigation with distilled water was capable to prevent the precipitate formation. The precipitate can be classified as a chemical smear layer.


Assuntos
Clorexidina , Hipoclorito de Sódio , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Clorexidina/farmacologia , Clorexidina/química , Ácido Edético , Microscopia Eletrônica de Varredura , Dente Canino , Irrigantes do Canal Radicular/farmacologia , Irrigantes do Canal Radicular/química , Água , Cavidade Pulpar , Preparo de Canal Radicular/métodos
4.
Int J Paediatr Dent ; 34(1): 3-10, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37038703

RESUMO

BACKGROUND: The literature is scanty regarding the effect of radiation therapy (RT) on the mechanical properties of immature permanent teeth. AIM: To evaluate the effect of RT on the fracture resistance of simulated immature teeth submitted to different types of root reinforcement. DESIGN: Sixty-four human teeth simulating the Cvek stage 3 of root development were distributed into eight groups (n = 8), according to exposure or not to RT (70 Gy) and the root reinforcement method: Group NR (control)-no reinforcement/no RT; Group NR + RT (control)-no reinforcement/RT; Group PO-tricalcium silicate-based cement (TS) apical plug/canal obturation/no RT; Group PO + RT-TS apical plug/canal obturation/RT; Group TS-canal filling with TS/no RT; Group TS + RT-canal filling with TS/RT; Group FP-TS apical plug/fibreglass post/no RT; and Group FP + RT-TS apical plug/fibreglass post/RT. Fracture resistance was determined using a universal testing machine (0.5 mm/min). RESULTS: In the intergroup comparison, nonirradiated teeth had higher fracture resistance (p < .05). Groups FP and FP + RT had higher fracture resistance (p < .001). CONCLUSION: Radiotherapy affected the fracture resistance of simulated immature teeth. Reinforcement with fibreglass posts increased the fracture resistance, regardless of the radiation.


Assuntos
Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Humanos , Compostos de Cálcio , Raiz Dentária , Silicatos
5.
Braz Dent J ; 34(4): 34-43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909640

RESUMO

This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal sealers (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer), and one epoxy resin-based sealer (AH Plus; control) were tested. The effect of heating on setting time (ST) and flowability were assessed according to ANSI/ADA 57 and ISO 6876 standards. Solubility and dimensional change (DC) of the set sealers were evaluated at 24 hours and after 30 days; the pH of the water used in the DC testing was also measured. Tests were repeated with heated sealers in an oven at 100 °C for 1 min. SEM and EDS analysis were performed. Data were analyzed using One-Way ANOVA and Tukey post-hoc tests (α=5%). Heating decreased the ST for AH Plus and EndoSequence (p<0.05). Heating reduced flowability (p<0.05) and increased pH for AH Plus (p<0.05). The solubility of Bio-C (dried specimens) was not in accordance with the ANSI/ADA standard. The solubility of EndoSequence was significantly higher (p<0.05) when it was heated and dried after 30 days. DC of Bio-C (24 h and 30 days), BioRoot-RCS (30 days) and AH Plus (24 h and 30 days) were not in accordance with the standards. SEM and EDS analysis showed significant changes in sealer microstructure after heating. In conclusion, heating decreased the ST and increased the solubility of EndoSequence BC sealer. No significant changes in flowability, DC, and pH were identified for all three tricalcium silicate sealers after heat application. However, all sealers had significant surface changes.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Calefação , Cavidade Pulpar , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de Materiais
6.
J Am Dent Assoc ; 154(10): 910-921.e4, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37598330

RESUMO

BACKGROUND: Identifying the presence of teeth in newborns is important as it may require immediate care. This study aimed to determine the worldwide prevalence of natal and neonatal teeth. TYPE OF STUDIES REVIEWED: Six electronic databases and the gray literature were searched on February 23, 2023 to identify observational studies reporting the prevalence of natal or neonatal teeth. Studies assuming natal and neonatal teeth as identical terms or not reporting prevalence indicators were excluded. The methodological quality of the studies was assessed using the Joanna Briggs Institute checklist for studies reporting prevalence data. The worldwide prevalence of natal and neonatal teeth was estimated via proportion meta-analysis using a ß-binomial model. Heterogeneity across studies was explored via subgroup analyses and meta-regression. RESULTS: None of the 23 included studies fulfilled all items of the methodological quality checklist. The worldwide prevalence of natal teeth was 34.55 (95% CI, 20.12 to 59.26) per 10,000, and the prevalence of neonatal teeth was 4.52 (95% CI, 2.59 to 17.91) per 10,000. Subgroup analysis by continent showed that the prevalence of natal teeth ranged from 11.26 (95% CI, 7.58 to 16.61) per 10,000 in Asia through 75.32 (95% CI, 51.11 to 99.86) per 10,000 in North America, and the prevalence of neonatal teeth ranged from 3.52 (95% CI, 1.73 to 7.06) per 10,000 in Europe through 6.01 (95% CI, 2.25 to 16.60) per 10,000 in South America. Meta-regression did not find a statistically significant association between prevalence rates and year of publication or sample size. PRACTICAL IMPLICATIONS: Approximately 1 in 289 newborns had natal teeth and 1 in 2,212 had neonatal teeth. Although this is not a high prevalence, professionals must be alert to identify these conditions, which often require immediate care.


Assuntos
Dentes Natais , Humanos , Recém-Nascido , Prevalência
7.
Braz. dent. j ; 34(4): 34-43, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520331

RESUMO

Abstract This study evaluated the effect of heating on the physicochemical properties and surface changes of tricalcium silicate sealers. Three tricalcium silicate root canal sealers (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer), and one epoxy resin-based sealer (AH Plus; control) were tested. The effect of heating on setting time (ST) and flowability were assessed according to ANSI/ADA 57 and ISO 6876 standards. Solubility and dimensional change (DC) of the set sealers were evaluated at 24 hours and after 30 days; the pH of the water used in the DC testing was also measured. Tests were repeated with heated sealers in an oven at 100 °C for 1 min. SEM and EDS analysis were performed. Data were analyzed using One-Way ANOVA and Tukey post-hoc tests (α=5%). Heating decreased the ST for AH Plus and EndoSequence (p<0.05). Heating reduced flowability (p<0.05) and increased pH for AH Plus (p<0.05). The solubility of Bio-C (dried specimens) was not in accordance with the ANSI/ADA standard. The solubility of EndoSequence was significantly higher (p<0.05) when it was heated and dried after 30 days. DC of Bio-C (24 h and 30 days), BioRoot-RCS (30 days) and AH Plus (24 h and 30 days) were not in accordance with the standards. SEM and EDS analysis showed significant changes in sealer microstructure after heating. In conclusion, heating decreased the ST and increased the solubility of EndoSequence BC sealer. No significant changes in flowability, DC, and pH were identified for all three tricalcium silicate sealers after heat application. However, all sealers had significant surface changes.


Resumo Este estudo avaliou o efeito do aquecimento nas propriedades físico-químicas e nas alterações superficiais de cimentos de silicato tricálcico. Três cimentos endodônticos de silicato tricálcico (Bio-C Sealer, BioRoot-RCS, EndoSequence BC Sealer) e um cimento à base de resina epóxi (AH Plus) foram testados para avaliar o efeito do aquecimento no tempo de presa (TP) e escoamento de acordo com as normas ANSI/ADA 57 e ISO 6876. A solubilidade e alteração dimensional (AD) dos cimentos foram avaliadas após 24 horas e 30 dias. O pH da água usada no teste de AD também foi medido. Os testes foram repetidos com cimentos aquecidos em um forno a 100 °C por 1 min. Análises em MEV e EDS foram realizadas. Os dados foram analisados pelos testes de ANOVA-1 via e post hoc de Tukey (α=5%). O aquecimento diminuiu o TP para AH Plus e EndoSequence (p<0,05). O aquecimento reduziu o escoamento (p<0,05) e aumentou o pH do AH Plus (p<0,05). A solubilidade do Bio-C (amostras desidratadas) não estava de acordo com o padrão ANSI/ADA. A solubilidade da EndoSequence foi significativamente maior (p<0,05) quando aquecida e desidratada após 30 dias. As AD de Bio-C (24 h e 30 dias), BioRoot-RCS (30 dias) e AH Plus (24 h e 30 dias) não estavam de acordo com as normas ADA e ISO. A análise em MEV e EDS mostrou alterações significativas na estrutura dos cimentos após aquecimento. Em conclusão, o aquecimento diminuiu o TP e aumentou a solubilidade do cimento EndoSequence BC. Não foram identificadas mudanças significativas no escoamento, AD e pH para os cimentos de silicato tricálcico após aquecimento. Porém, todos os cimentos tiveram alterações significativas na superfície.

8.
J Appl Oral Sci ; 31: e20220444, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37132699

RESUMO

Few long-term studies assess the discoloration induced by hydraulic calcium silicate-based cement on dental structures. In addition, as far as we know, no long-term study has assessed the discoloration induced by these cement on composite resin. This in vitro study aimed to assess, during a period of two years, the discoloration potential of different hydraulic calcium silicate-based cements (hCSCs) on the enamel/dentin structure and composite resin restoration. A total of 40 enamel/dentin discs were obtained from bovine incisors, and 40 composite resin discs (10 mm in diameter × 2 mm thick) were fabricated. A 0.8 mm-deep cavity was made in the center of each disc and filled with the following hCSCs (n=10): Original MTA (Angelus); MTA Repair HP (Angelus); NeoMTA Plus (Avalon); and Biodentine (Septodont). An initial color measurement was performed (T0 - baseline). After 7, 15, 30, 45, 90, 300 days, and two years, new color measurements were performed to determine the color (ΔE00), lightness (ΔL'), chroma (ΔC'), hue differences (ΔH'), and whiteness index (WID). For enamel/dentin, the ΔE00 was significant among groups and periods (p<0.05). NeoMTA Plus had the greatest ΔE00. The NeoMTA Plus group had the greatest ΔE00 after two years for composite resin. Significant reduction in lightness was observed for all groups after two years (p<0.05). The most significant WID values were observed after 30 days for Biodentine (enamel/dentin) and MTA Repair HP groups (composite resin) (p<0.05). The hCSCs changed the colorimetric behavior of both substrates, leading to greater darkening over time. The Bi2O3 in the Original MTA seems relevant in the short periods of color change assessment.


Assuntos
Compostos de Cálcio , Resinas Compostas , Animais , Bovinos , Resinas Compostas/efeitos adversos , Resinas Compostas/química , Compostos de Cálcio/efeitos adversos , Silicatos/efeitos adversos , Cimentos Dentários/efeitos adversos , Óxidos , Combinação de Medicamentos , Teste de Materiais , Compostos de Alumínio/efeitos adversos , Cimentos de Resina/efeitos adversos
9.
Restor Dent Endod ; 48(1): e3, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36875816

RESUMO

Objectives: This study evaluated the effect of different nanoparticulated zinc oxide (nano-ZnO) and conventional-ZnO ratios on the physicochemical properties of calcium aluminate cement (CAC). Materials and Methods: The conventional-ZnO and nano-ZnO were added to the cement powder in the following proportions: G1 (20% conventional-ZnO), G2 (15% conventional-ZnO + 5% nano-ZnO), G3 (12% conventional-ZnO + 3% nano-ZnO) and G4 (10% conventional-ZnO + 5% nano-ZnO). The radiopacity (Rad), setting time (Set), dimensional change (Dc), solubility (Sol), compressive strength (Cst), and pH were evaluated. The nano-ZnO and CAC containing conventional-ZnO were also assessed using scanning electron microscopy, transmission electron microscopy, and energy-dispersive X-ray spectroscopy. Radiopacity data were analyzed by the 1-way analysis of variance (ANOVA) and Bonferroni tests (p < 0.05). The data of the other properties were analyzed by the ANOVA, Tukey, and Fisher tests (p < 0.05). Results: The nano-ZnO and CAC containing conventional-ZnO powders presented particles with few impurities and nanometric and micrometric sizes, respectively. G1 had the highest Rad mean value (p < 0.05). When compared to G1, groups containing nano-ZnO had a significant reduction in the Set (p < 0.05) and lower values of Dc at 24 hours (p < 0.05). The Cst was higher for G4, with a significant difference for the other groups (p < 0.05). The Sol did not present significant differences among groups (p > 0.05). Conclusions: The addition of nano-ZnO to CAC improved its dimensional change, setting time, and compressive strength, which may be promising for the clinical performance of this cement.

10.
J Mech Behav Biomed Mater ; 140: 105699, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36753848

RESUMO

The use of fluorescent dyes in microscopy studies is frequent. Therefore, it is important to investigate whether these compounds may alter the physicochemical properties of materials in which they are incorporated to avoid methodological biases. This study evaluated the physicochemical properties of two endodontic sealers containing dry or diluted rhodamine B. Six groups were evaluated: AH Plus and MTA Fillapex in their original composition and mixed with 0.1% dry or diluted rhodamine. Push-out test was applied to assess the bond strength to root dentin. ANSI-ADA No. 57 and ISO No. 6876:2012 specifications were followed to evaluate flowability, setting time, and solubility of the sealers. pH changes were assessed after 24 h, 7, and 30 days. Intergroup comparisons were analyzed by ANOVA complemented by Tukey's post-hoc test; comparisons among periods were analyzed by Wilcoxon and Friedman tests. The incorporation of dry rhodamine decreased the bond strength and prolonged the setting time of AH Plus. The incorporation of diluted rhodamine decreased the setting time and increased the flowability of MTA Fillapex. Diluted rhodamine promoted pH reduction of AH Plus after 24 h and dry rhodamine after 7 days. Rhodamine incorporation promoted pH reduction after 30 days for MTA Fillapex. Solubility was not affected. In conclusion, the incorporation of diluted rhodamine changed the properties of MTA Fillapex, and the incorporation of dry rhodamine changed the properties of AH Plus. Previous dilution of rhodamine did not severely compromise the physicochemical properties of AH Plus and may be suggested to assess its penetrability.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Resinas Epóxi/química , Compostos de Cálcio/química , Óxidos/química , Rodaminas , Solubilidade , Combinação de Medicamentos , Silicatos/química , Teste de Materiais
11.
J Endod ; 49(4): 369-381.e11, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36754253

RESUMO

INTRODUCTION: The overall prevalence of maxillary sinusitis of odontogenic origin (MSOO) is still unknown. Therefore, this study aimed to determine the pooled prevalence of MSOO and verify associations between different odontogenic conditions and MSOO. METHODS: Six electronic databases and the gray literature were searched on August 25, 2022. Two independent reviewers selected observational studies reporting the prevalence of MSOO and associated conditions in adults. Studies that did not use computed tomography for diagnosis were excluded. The methodological quality of the studies was assessed using the Joanna Briggs Institute Critical Appraisal Checklist for Cross-Sectional Studies. Data were analyzed by proportion and association meta-analyses. The certainty of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation approach. RESULTS: Thirty-eight studies were included in the qualitative analysis and thirty-one in the meta-analyses. Only 12 studies (31.6%) fulfilled all items of the methodological quality checklist. Overall, the studies reported prevalence measures per maxillary sinus or patient. Thus, the pooled prevalence of MSOO was 51% per sinus (95% confidence interval [CI] [40%-61%]) and 50% per patient (95% CI [41%-59%]). Apical lesion (odds ratio [OR]: 4.03, 95% CI [2.26-7.19]), periodontitis (OR: 5.49, 95% CI [2.27-13.24]), moderate (OR: 2.57, 95% CI [1.85-3.57]) and severe bone loss (OR: 13.80, 95% CI [2.81-67.85] were significantly associated with MSOO. The certainty of the evidence for the associations was very low. CONCLUSIONS: The pooled prevalence of MSOO on computed tomography assessment was 51% per maxillary sinus and 50% per patient. Therefore, half of the maxillary sinusitis may be of odontogenic origin. Apical lesion, periodontitis, and moderate and severe bone loss were significantly associated with MSOO.


Assuntos
Sinusite Maxilar , Adulto , Humanos , Sinusite Maxilar/diagnóstico por imagem , Sinusite Maxilar/epidemiologia , Sinusite Maxilar/etiologia , Prevalência , Estudos Transversais , Seio Maxilar , Tomografia Computadorizada por Raios X
12.
Aust Endod J ; 49 Suppl 1: 122-131, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36251405

RESUMO

This study investigated the effect of radiation timing on the bond strength of resin cement to intraradicular dentine. Fifty human teeth were distributed into 5 groups (n = 10): Control (nonirradiated teeth), Before-RCT (teeth irradiated before root canal treatment), After-CH (teeth irradiated after canal preparation and placement of calcium hydroxide intracanal dressing), After-RCT (teeth irradiated after completion of root canal treatment) and After-FPL (teeth irradiated after luting of a glass fibre post). Each tooth received 70 Gy irradiation. The roots were sectioned for push-out strength testing. After-RCT and After-FPL groups had significantly lower push-out strength than the control at the middle third (p < 0.05). Control and After-CH groups had a higher percentage of cohesive dentine failure. Radiotherapy after root canal obturation and post luting adversely affected the adhesiveness of resin cement to intraradicular dentine. Teeth irradiated before root canal treatment and after placement of calcium hydroxide had the best performance.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Humanos , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Hidróxido de Cálcio/uso terapêutico , Dentina , Cavidade Pulpar , Preparo de Canal Radicular , Teste de Materiais , Vidro/química , Análise do Estresse Dentário
13.
J. appl. oral sci ; 31: e20220444, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430630

RESUMO

Abstract Few long-term studies assess the discoloration induced by hydraulic calcium silicate-based cement on dental structures. In addition, as far as we know, no long-term study has assessed the discoloration induced by these cement on composite resin. Objective This in vitro study aimed to assess, during a period of two years, the discoloration potential of different hydraulic calcium silicate-based cements (hCSCs) on the enamel/dentin structure and composite resin restoration. Methodology A total of 40 enamel/dentin discs were obtained from bovine incisors, and 40 composite resin discs (10 mm in diameter × 2 mm thick) were fabricated. A 0.8 mm-deep cavity was made in the center of each disc and filled with the following hCSCs (n=10): Original MTA (Angelus); MTA Repair HP (Angelus); NeoMTA Plus (Avalon); and Biodentine (Septodont). An initial color measurement was performed (T0 - baseline). After 7, 15, 30, 45, 90, 300 days, and two years, new color measurements were performed to determine the color (ΔE00), lightness (ΔL'), chroma (ΔC'), hue differences (ΔH'), and whiteness index (WID). Results For enamel/dentin, the ΔE00 was significant among groups and periods (p<0.05). NeoMTA Plus had the greatest ΔE00. The NeoMTA Plus group had the greatest ΔE00 after two years for composite resin. Significant reduction in lightness was observed for all groups after two years (p<0.05). The most significant WID values were observed after 30 days for Biodentine (enamel/dentin) and MTA Repair HP groups (composite resin) (p<0.05). Conclusions The hCSCs changed the colorimetric behavior of both substrates, leading to greater darkening over time. The Bi2O3 in the Original MTA seems relevant in the short periods of color change assessment.

14.
Braz Dent J ; 33(5): 26-34, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36287496

RESUMO

This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO2) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted human teeth had their crowns interposed between the POs and an optical simulator, which emulated the SpO2 and heart beats per minute (bpm) at HP (100% SpO2/75 bpm) and LP (86% SpO2/75 bpm) modes. Afterwards, the palatine/lingual surfaces of the dental crowns were worn with diamond drills. The reading of SpO2 was performed again using the POs alternately through the buccal surface of each dental crown. Data were analyzed by the Wilcoxon, Mann-Whitney and Kendall Tau-b tests (α=5%). The results showed significant difference at the HP and LP modes in the SpO2 readouts through the different dental thicknesses with the use of BCI, and at the LP mode with the use of Sense 10, which had a significant linear correlation (p<0.0001) and lower SpO2 readout values in relation to the increase of the dental thickness. Irrespective of tooth thickness, Sense 10 had significantly higher readout values (p<0.0001) than BCI at both perfusion modes. The interposition of different thicknesses of enamel and dentin influenced the POs measurement of SpO2, specially at the low perfusion mode. The POs were more accurate in SpO2 measurement when simulated perfusion levels were higher.


Assuntos
Oximetria , Saturação de Oxigênio , Humanos , Oxigênio , Esmalte Dentário , Diamante
15.
Braz. dent. j ; 33(5): 26-34, Sep.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1403786

RESUMO

Abstract This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO2) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted human teeth had their crowns interposed between the POs and an optical simulator, which emulated the SpO2 and heart beats per minute (bpm) at HP (100% SpO2/75 bpm) and LP (86% SpO2/75 bpm) modes. Afterwards, the palatine/lingual surfaces of the dental crowns were worn with diamond drills. The reading of SpO2 was performed again using the POs alternately through the buccal surface of each dental crown. Data were analyzed by the Wilcoxon, Mann-Whitney and Kendall Tau-b tests (α=5%). The results showed significant difference at the HP and LP modes in the SpO2 readouts through the different dental thicknesses with the use of BCI, and at the LP mode with the use of Sense 10, which had a significant linear correlation (p<0.0001) and lower SpO2 readout values in relation to the increase of the dental thickness. Irrespective of tooth thickness, Sense 10 had significantly higher readout values (p<0.0001) than BCI at both perfusion modes. The interposition of different thicknesses of enamel and dentin influenced the POs measurement of SpO2, specially at the low perfusion mode. The POs were more accurate in SpO2 measurement when simulated perfusion levels were higher.


Resumo Este estudo avaliou a influência de diferentes espessuras de esmalte e dentina na medição dos níveis de saturação de oxigênio (SpO2) em alta (HP) e baixa (LP) perfusão sanguínea, comparando os valores obtidos em dois oxímetros de pulso (OPs) diferentes, BCI e Sense 10. Trinta dentes recém-extraídos de humanos tiveram suas coroas interpostas entre os OPs e um simulador óptico, que simulava a SpO2 e os batimentos cardíacos por minuto (bpm) nos modos de HP (100% SpO2 / 75 bpm) e LP (86% SpO2 / 75 bpm). Após, as superfícies palatinas / linguais dos dentes foram desgastadas com brocas de diamantadas. A leitura da SpO2 foi realizada novamente usando os dois OPs alternadamente através da face vestibular de cada coroa dental. Os dados foram analisados ​​pelos testes Wilcoxon, Mann-Whitney e Kendall Tau-b (α = 5%). Os resultados mostraram diferença significativa nos modos HP e LP nas leituras de SpO2 através das diferentes espessuras dentárias com o uso do BCI, e no modo LP com o uso do Sense 10, que teve correlação linear significativa (p <0,0001) e menores valores de leitura de SpO2 em relação ao aumento da espessura dentária. Independentemente da espessura do dente, o Sense 10 apresentou valores de leitura significativamente maiores (p <0,0001) do que o BCI em ambos os modos de perfusão. A interposição de diferentes espessuras de esmalte e dentina influenciaram a mensuração da SpO2 pelos OPs, especialmente no modo de baixa perfusão. Os POs foram mais precisos na mensuração da SpO2 quando os níveis simulados de perfusão foram maiores.

16.
Clin Oral Investig ; 26(10): 6043-6060, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35852628

RESUMO

OBJECTIVES: The use of natural products for pulp therapy has experienced a remarkable advancement in recent years. The aim was to provide a critical appraisal of the safety and efficacy of natural products for endodontic therapy in primary teeth and verify whether their uses in clinical practice have sufficient evidence. MATERIALS AND METHODS: Two reviewers searched ten databases (Cochrane, DOSS, Embase, Google Scholar, LILACS, OpenGrey, Proquest, PubMed, Scopus, and Web of Science) until January 2022, identifying references that evaluated the safety and efficacy of the use of natural products for endodontic therapy in primary teeth. Cohort, randomized, and non-randomized clinical trials were included. RESULTS: A total of 3583 references were initially identified. From the 63 studies retrieved for full-text reading, 37 fulfilled the selection criteria and were included in the qualitative analysis. The studies investigated 19 natural products for pulpotomy medicament, irrigating solution, intracanal medication, and root canal filling material. Most studies showed similar efficacy of natural products and their control groups; however, many methodological biases and concerns about the safety and efficacy of natural products were identified, questioning their clinical applicability. CONCLUSIONS: The included studies provided insufficient evidence to support safe and effective clinical application of natural products for endodontic therapy in primary teeth. Future well-designed studies with representative samples are needed to support the use of natural products for endodontic therapy in primary teeth. CLINICAL RELEVANCE: The use of natural products for endodontic therapy in primary teeth requires caution by clinicians, due to the insufficient available evidence.


Assuntos
Produtos Biológicos , Materiais Restauradores do Canal Radicular , Produtos Biológicos/uso terapêutico , Humanos , Pulpotomia , Materiais Restauradores do Canal Radicular/uso terapêutico , Tratamento do Canal Radicular , Dente Decíduo
17.
Int Endod J ; 55(10): 989-1009, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35808837

RESUMO

BACKGROUND: The lack of a well-defined apical constriction in primary teeth raises concerns regarding the accuracy of electronic apex locators (EALs) for measuring working length. OBJECTIVES: To evaluate the accuracy of EALs in determining working length in primary teeth pulpectomies. METHODS: Two reviewers searched ten databases up to September 2021. Clinical studies evaluating the accuracy of the electronic measurement of working length in primary teeth pulpectomies were included. Studies without a comparison group, with samples smaller than ten root canals, and that did not use a multiple frequency EAL were excluded. A meta-analysis was conducted to assess the paired differences in mean lengths between measurements obtained by electronic and comparative methods. In addition, a meta-analysis of proportion was applied according to the level of difference between the measures. The risk of bias and applicability of the studies were assessed using the QUADAS-2 tool. The certainty of evidence was assessed with the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. RESULTS: Twenty-nine studies were included in the qualitative analysis and twenty-three in the quantitative analysis. The methods of comparison for the electronic measurement were the radiographic method, radiovisiographic, scanning electron microscopy, and direct visualization. The meta-analysis showed that the electronic measurement tends to be shorter than radiographic measurement, while the other methods showed no difference. The proportion analysis showed a higher pooled proportion of difference values between electronic and comparative measurements within -0.5 to +0.5 mm (69.31%). The certainty of the evidence suggested very low confidence in estimating the outcome. DISCUSSION: The results of this review denote a good performance of the EALs in determining working length in primary teeth pulpectomies. However, these results are based on clinical studies with low methodological quality and high heterogeneity, which require careful interpretation for clinical practice. CONCLUSIONS: Although the results suggest acceptable accuracy of EALs in determining working length in primary teeth pulpectomies, the low quality of the included studies and the very low certainty of the evidence require clinicians to interpret these results with caution. More robust evidence is required to support that these devices are accurate for primary teeth. REGISTRATION: CRD42021277414 (PROSPERO).


Assuntos
Pulpectomia , Ápice Dentário , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Eletrônica , Odontometria , Preparo de Canal Radicular , Ápice Dentário/diagnóstico por imagem , Ápice Dentário/cirurgia , Dente Decíduo
18.
Braz Dent J ; 32(3): 21-31, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34755787

RESUMO

This study assessed the fracture resistance of simulated immature teeth reinforced with calcium aluminate cement (CAC) or mineral trioxide aggregate (MTA) containing calcium carbonate nanoparticles (nano-CaCO3). The microstructural arrangement of the cements and their chemical constitution were also evaluated. Forty-eight canines simulating immature teeth were distributed into 6 groups (n=8): Negative control - no apical plug or root canal filling; CAC - apical plug with CAC; CAC/nano-CaCO3 - apical plug with CAC+5% nano-CaCO3; MTA - apical plug with MTA; MTA/nano-CaCO3 - apical plug with MTA+5% nano-CaCO3; and Positive control - root canal filling with MTA. The fracture resistance was evaluated in a universal testing machine. Samples of the cements were analyzed under Scanning Electron Microscope (SEM) to determine their microstructural arrangement. Chemical analysis of the cements was performed by Energy Dispersive X-ray Spectroscopy (EDS). The fracture resistance of CAC/nano-CaCO3 was significantly higher than the negative control (p<0.05). There was no significant difference among the other groups (p>0.05). Both cements had a more regular microstructure with the addition of nano-CaCO3. MTA samples had more calcium available in soluble forms than CAC. The addition of nano-CaCO3 to CAC increased the fracture resistance of teeth in comparison with the non-reinforced teeth. The microstructure of both cements containing nano-CaCO3 was similar, with a more homogeneous distribution of lamellar- and prismatic-shaped crystals. MTA had more calcium available in soluble forms than CAC.


Assuntos
Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Compostos de Alumínio , Compostos de Cálcio , Cimentos Dentários , Combinação de Medicamentos , Humanos , Óxidos , Obturação do Canal Radicular , Silicatos , Ápice Dentário
19.
Braz. dent. j ; 32(6): 115-123, Nov.-Dec. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1355837

RESUMO

Abstract This article reported two clinical cases in which the guided endodontics was used to perform the access to the root canals. The first case presents a 40-year-old female with a history of pain related to the left maxillary canine. After radiographic examination, the presence of severe calcification up to the apical third of the root canal, associated with a periapical radiolucency, was noted. In the second case, an 85-year-old male was referred to our service with pain upon palpation, at the right mandibular first molar. The radiographic images revealed the presence of endodontic treatment and a fiberglass post in the distal root canal, which was associated with extrusion of the filling material and a periapical lesion. The 3D-guides were planned based on cone beam computed tomography and intraoral digital scanning, which were aligned using a specific software. Therefore, implant drills could be guided up to the root canal length required for each case. In the first case, a surgical root canal was created and the patient was free of signs and symptoms after the treatment was completed. In the second case, it was observed that the fiber post was worn by the drill, allowing free access to the filling material. It was possible to perform the endodontic reintervention in a more predictable way and in less time. In both cases, the use of the guided endodontics allowed the preservation of a large part of the dental structure. The procedures were performed faster, without the occurrence of fractures and perforations.


Resumo Este artigo relatou dois casos clínicos em que a endodontia guiada foi utilizada para realizar o acesso aos canais radiculares. O primeiro caso apresenta uma mulher de 40 anos com história de dor relacionada ao canino superior esquerdo. Após exame radiográfico, notou-se a presença de calcificação acentuada até o terço apical do canal radicular, associada a radioluscência periapical. No segundo caso, um homem de 85 anos foi encaminhado ao nosso serviço com dor à palpação no primeiro molar inferior direito. As imagens radiográficas revelaram a presença de tratamento endodôntico e pino de fibra de vidro no canal radicular distal, que estava associado à extrusão do material obturador e lesão periapical. Os guias-3D foram planejados com base em tomografia computadorizada de feixe cônico e escaneamento intraoral digital, os quais foram alinhados por meio de um software específico. Desta forma, brocas de implante puderam ser guiadas até o comprimento necessário do canal radicular para cada caso. No primeiro caso, foi confeccionado um canal radicular cirúrgico e o paciente ficou sem sinais e sintomas após o término do tratamento. No segundo caso, observou-se que o pino de fibra foi desgastado pela broca, permitindo o livre acesso ao material obturador. Foi possível realizar a reintervenção endodôntica de forma mais previsível e em menos tempo. Em ambos os casos, o uso da endodôntica guiada permitiu a preservação de grande parte da estrutura dentária. Os procedimentos foram realizados com maior agilidade, sem a ocorrência de fraturas e perfurações.

20.
Braz. dent. j ; 32(3): 21-31, May-June 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1345507

RESUMO

Abstract This study assessed the fracture resistance of simulated immature teeth reinforced with calcium aluminate cement (CAC) or mineral trioxide aggregate (MTA) containing calcium carbonate nanoparticles (nano-CaCO3). The microstructural arrangement of the cements and their chemical constitution were also evaluated. Forty-eight canines simulating immature teeth were distributed into 6 groups (n=8): Negative control - no apical plug or root canal filling; CAC - apical plug with CAC; CAC/nano-CaCO3 - apical plug with CAC+5% nano-CaCO3; MTA - apical plug with MTA; MTA/nano-CaCO3 - apical plug with MTA+5% nano-CaCO3; and Positive control - root canal filling with MTA. The fracture resistance was evaluated in a universal testing machine. Samples of the cements were analyzed under Scanning Electron Microscope (SEM) to determine their microstructural arrangement. Chemical analysis of the cements was performed by Energy Dispersive X-ray Spectroscopy (EDS). The fracture resistance of CAC/nano-CaCO3 was significantly higher than the negative control (p<0.05). There was no significant difference among the other groups (p>0.05). Both cements had a more regular microstructure with the addition of nano-CaCO3. MTA samples had more calcium available in soluble forms than CAC. The addition of nano-CaCO3 to CAC increased the fracture resistance of teeth in comparison with the non-reinforced teeth. The microstructure of both cements containing nano-CaCO3 was similar, with a more homogeneous distribution of lamellar- and prismatic-shaped crystals. MTA had more calcium available in soluble forms than CAC.


Resumo Este estudo avaliou a resistência à fratura de dentes imaturos simulados reforçados com cimento de aluminato de cálcio (CAC) ou trióxido agregado mineral (MTA) contendo nanopartículas de carbonato de cálcio (nano-CaCO3). O arranjo microestrutural dos cimentos e sua constituição química também foram avaliados. Quarenta e oito caninos simulando dentes imaturos foram distribuídos em 6 grupos (n=8): Controle negativo - sem plug apical ou obturação do canal radicular; CAC - plug apical com CAC; CAC/nano-CaCO3 - plug apical com CAC + 5% nano-CaCO3; MTA - plug apical com MTA; MTA/nano-CaCO3 - plug apical com MTA + 5% nano-CaCO3; e Controle positivo - obturação dos canais radiculares com MTA. A resistência à fratura foi avaliada em máquina universal de ensaios. Amostras dos cimentos foram analisadas em Microscópio Eletrônico de Varredura (MEV) para determinar seu arranjo microestrutural. A análise química dos cimentos foi realizada por Espectroscopia de Energia Dispersiva de Raio-X (EDS). A resistência à fratura de CAC/nano-CaCO3 foi significativamente maior do que o controle negativo (p<0,05). Não houve diferença significativa entre os outros grupos (p>0,05). Ambos os cimentos apresentaram microestrutura mais regular com a adição de nano-CaCO3. As amostras de MTA apresentaram mais cálcio disponível em formas solúveis do que CAC. A adição de nano-CaCO3 ao CAC aumentou a resistência à fratura dos dentes em comparação aos dentes não reforçados. A microestrutura de ambos os cimentos contendo nano-CaCO3 foi semelhante, com uma distribuição mais homogênea de cristais de formato lamelar e prismático. MTA apresentou mais cálcio disponível nas formas solúveis do que CAC.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Óxidos , Obturação do Canal Radicular , Silicatos , Compostos de Cálcio , Compostos de Alumínio , Ápice Dentário , Cimentos Dentários , Combinação de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...